Development of specialized controllers

Noria control and protection device / transproter PKZN-7

The PKZN-7 control and protection device is designed to control the condition of elevator transport equipment - nori and conveyors. It is used as part of the System of control and protection of transport equipment.

What does it provide?

  • Electrical power supply and signal reception of movement sensors, belt speed, position, filling, clogging, level, temperature, current;
  • Display of data received from sensors and operating modes on the display; limit value settings;
  • Issuance of emergency notifications;
  • Breakage of the power contactor switching line of the engine in the event of an emergency alarm;
  • Data transfer to an external PC (PLC) for integration into the general process management system.
  •  

    The device has a self-monitoring function. At the same time, programmed parameter deviations in percentages are displayed on the display, and complete testing of external and internal signal circuits and tripping circuit is performed.

    In the basic version, the device has six galvanically isolated high-speed inputs for connecting discrete sensors of movement, speed, position, filling, clogging, level, one control input for turning on the power contactor of the electric motor and turning on the emergency notification, one output for turning off the power contactor of the electric motor, one port RS- 485 connection to a PC or PLC.

    Variant of the PKZN / VIT-7 device when ordering. The basic equipment can be expanded by installing boards that expand the functionality:

    • PTR-7pkzn thermometry board for working with temperature sensors of the PTC, NTC, Pt100 type;
    • P1W-7pkzn thermometry board for working with thermosensors type DS18B20;
    • PLC-7pkzn weighing board;
    • PKE-7pkzn engine current and voltage control board.
     

    The main technical characteristics of the device in the basic version:

    Power supply

    Modification

    PKZN-7/220

    PKZN-7/24

    Supply voltage, V

    ~85 … 264

    18 … 28

    Consumed power, no more than, W

    25

    20

    Power supply frequency, Hz

    47 … 440

    -

    Output voltage of the built-in power supply of external sensors, V

    24±3

    -

    The maximum output current of the built-in power supply of external sensors, mA

    400

    -

    High-speed entrances

    Number of entrances, pcs

    6

    Maximum frequency of input pulses, Hz

    1000

    Minimum pulse duration, ms

    1

    Input voltage, V

    18 … 28

    Maximum current of one input, mA

    25

    Signal level of "logical unit" for constant voltage, V

    15 ... 27 (at least 4.5)

    The level of the "logical zero" signal for constant voltage, V

    0 ... 5 (no more than 1,5)

    Type of galvanic isolation

    optoisolation

    Electrical durability of insulation, V

    1500

    Power contactor control input

    Voltage in the contactor control circuit

    ~220V

    24V

    Number of entrances, pcs

    1

    Input current, mA

    6

    20

    Exits

    Output destination

    Enable emergency notification

    Break in the control circuit of the power contactor

    Exit designation

    "Accident"

    "Stop"

    Number of outputs, pcs

    2

    Output type

    Relay, dry contact type

    The maximum switching voltage, V

    250

    Minimum switching voltage, V

    10

    Rated current (Load power)    AC1

                                                                                AC15

                                                                                AC3

                                                                                DC1

                                                                                DC13

    16 A / 250 V AC

    3 A / 120 V 1,5 A / 240 V  (B300)

    750 W  (1-phase electric motor)

    16 A / 24 V DC 

    0,22 A / 120 V 0,1 A / 250 V  (R300)

    Minimum switching current, mA

    10

    Minimum peak current, A

    30

    Continuous current load, A

    16

    Electrical and mechanical resource of cycles

    More than 10000 (20 A, 250 V AC, 85 °C)

    PC (PLC) communication interface

    Interface type

    RS-485

    Communication protocol

    ModBus RTU

    Data transfer format

    7 or 8 bits, parity

    Transmission speed, bit/s

    2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200

    Cable length, m, no more than

    1200 (KIPEV 1×2×0.6 TU 16.K99-008– 2001 or similar)

    Network address of the device

    1 … 32

    General Information

    The degree of protection of the housing according to DSTU ISO 14254–96

    IP-65

    Overall dimensions, mm

    190 х 190 х 55

    Weight, kg

    1,05

    Terms of use

    Operating temperature, °С

    -10 … +50

    Storage temperature, °С

    -25 … +65

    Upper limit of relative air humidity at 25°С, %

    80

    Atmospheric pressure, kPa

    80 … 110

    Height above sea level no more than, m

    2000

    Immunity

    Meets the requirements for resistance to interference in accordance with DSTU ISO R 51841 and DSTU ISO R 51522 for class A equipment

    Radiation level of radio interference

    Corresponds to the standards established for class B equipment according to DSTU ISO R 51318.22 (SISPR 22–97)

    Resistance to air electric discharge, kV

    ± 8

     

    More about the device:

    Leave an application
    CAPTCHA
    This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
    Write to us
    CAPTCHA
    This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
    Order service now!
    CAPTCHA
    This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.